To place order give missed call on  022 – 39560561

Cart

Product Details

1,965.00

Electrode Storage Solution

HI70300L is a storage solution prepared with reagent grade chemicals that can be used to ensure optimum performance of your pH and ORP electrodes. It is necessary to store a pH electrode in a solution in order to keep the glass membrane of the pH electrode hydrated. Ideally a storage solution should be used; never store an electrode in distilled or deionized water. The Hanna Instruments storage solution is specifically formulated to minimize microbial growth and to prevent any effects of diffusion/osmotic from storing a probe in a solution with the highly concentrated inner reference electrolyte. Storing your pH and/or ORP electrodes in a storage solution will also keep the junction clear. Maintaining the hydrated layer and clear junction will help to ensure a fast and reliable measurement. In the case of cleaning your pH electrode in one of our cleaning solutions, we recommend soaking the electrode in the HI70300L storage solution for at least one hour before taking measurements.

 

  • Special formulation to minimize microbial growth and osmotic/diffusion effects between the solution and inner reference electrolyte.
  • Air tight bottle with tamper-proof seal
  • Each bottle marked with lot number and expiration date.
  • Manufactured specifically for pH and ORP electrodes

 

Details

HI70300L is a solution that can be used to store your pH electrode*. To ensure an optimum response time, the glass sensor tip and the reference junction of the pH electrode should be kept moist and not be allowed to dry out when not in use. Placing the electrode in a small glass filled with storage solution or replacing the solution in the protective cap is a suitable way to store the electrode. The HI70300L should also be used to rehydrate the electrode after a cleaning procedure by soaking for at least one hour before taking measurements. 

* Never store pH or ORP electrodes in distilled or deionized water. Doing so will shorten the life of the sensor. 

 

  • Ensures quality and freshness of solution

  • Hanna storage solutions are specially formulated to have an expiration of 5 years from manufacture for an unopened bottle.

SKU: HI70300L Category: Tag:

Share this product

Description

HI70300L is a storage solution prepared with reagent grade chemicals that can be used to ensure optimum performance of your pH and ORP electrodes. It is necessary to store a pH electrode in a solution in order to keep the glass membrane of the pH electrode hydrated. Ideally a storage solution should be used; never store an electrode in distilled or deionized water. The Hanna Instruments storage solution is specifically formulated to minimize microbial growth and to prevent any effects of diffusion/osmotic from storing a probe in a solution with the highly concentrated inner reference electrolyte. Storing your pH and/or ORP electrodes in a storage solution will also keep the junction clear. Maintaining the hydrated layer and clear junction will help to ensure a fast and reliable measurement. In the case of cleaning your pH electrode in one of our cleaning solutions, we recommend soaking the electrode in the HI70300L storage solution for at least one hour before taking measurements.

 

  • Special formulation to minimize microbial growth and osmotic/diffusion effects between the solution and inner reference electrolyte.
  • Air tight bottle with tamper-proof seal
  • Each bottle marked with lot number and expiration date.
  • Manufactured specifically for pH and ORP electrodes

 

Details

HI70300L is a solution that can be used to store your pH electrode*. To ensure an optimum response time, the glass sensor tip and the reference junction of the pH electrode should be kept moist and not be allowed to dry out when not in use. Placing the electrode in a small glass filled with storage solution or replacing the solution in the protective cap is a suitable way to store the electrode. The HI70300L should also be used to rehydrate the electrode after a cleaning procedure by soaking for at least one hour before taking measurements. 

* Never store pH or ORP electrodes in distilled or deionized water. Doing so will shorten the life of the sensor. 

 

  • Ensures quality and freshness of solution

  • Hanna storage solutions are specially formulated to have an expiration of 5 years from manufacture for an unopened bottle.

Additional information

Weight 500 kg

Reviews

There are no reviews yet.

Be the first to review “Electrode Storage Solution”

Your email address will not be published. Required fields are marked *

Talk to us...